| = sPAPR Dynamic Reconfiguration = | 
 |  | 
 | sPAPR/"pseries" guests make use of a facility called dynamic-reconfiguration | 
 | to handle hotplugging of dynamic "physical" resources like PCI cards, or | 
 | "logical"/paravirtual resources like memory, CPUs, and "physical" | 
 | host-bridges, which are generally managed by the host/hypervisor and provided | 
 | to guests as virtualized resources. The specifics of dynamic-reconfiguration | 
 | are documented extensively in PAPR+ v2.7, Section 13.1. This document | 
 | provides a summary of that information as it applies to the implementation | 
 | within QEMU. | 
 |  | 
 | == Dynamic-reconfiguration Connectors == | 
 |  | 
 | To manage hotplug/unplug of these resources, a firmware abstraction known as | 
 | a Dynamic Resource Connector (DRC) is used to assign a particular dynamic | 
 | resource to the guest, and provide an interface for the guest to manage | 
 | configuration/removal of the resource associated with it. | 
 |  | 
 | == Device-tree description of DRCs == | 
 |  | 
 | A set of 4 Open Firmware device tree array properties are used to describe | 
 | the name/index/power-domain/type of each DRC allocated to a guest at | 
 | boot-time. There may be multiple sets of these arrays, rooted at different | 
 | paths in the device tree depending on the type of resource the DRCs manage. | 
 |  | 
 | In some cases, the DRCs themselves may be provided by a dynamic resource, | 
 | such as the DRCs managing PCI slots on a hotplugged PHB. In this case the | 
 | arrays would be fetched as part of the device tree retrieval interfaces | 
 | for hotplugged resources described under "Guest->Host interface". | 
 |  | 
 | The array properties are described below. Each entry/element in an array | 
 | describes the DRC identified by the element in the corresponding position | 
 | of ibm,drc-indexes: | 
 |  | 
 | ibm,drc-names: | 
 |   first 4-bytes: BE-encoded integer denoting the number of entries | 
 |   each entry: a NULL-terminated <name> string encoded as a byte array | 
 |  | 
 |   <name> values for logical/virtual resources are defined in PAPR+ v2.7, | 
 |   Section 13.5.2.4, and basically consist of the type of the resource | 
 |   followed by a space and a numerical value that's unique across resources | 
 |   of that type. | 
 |  | 
 |   <name> values for "physical" resources such as PCI or VIO devices are | 
 |   defined as being "location codes", which are the "location labels" of | 
 |   each encapsulating device, starting from the chassis down to the | 
 |   individual slot for the device, concatenated by a hyphen. This provides | 
 |   a mapping of resources to a physical location in a chassis for debugging | 
 |   purposes. For QEMU, this mapping is less important, so we assign a | 
 |   location code that conforms to naming specifications, but is simply a | 
 |   location label for the slot by itself to simplify the implementation. | 
 |   The naming convention for location labels is documented in detail in | 
 |   PAPR+ v2.7, Section 12.3.1.5, and in our case amounts to using "C<n>" | 
 |   for PCI/VIO device slots, where <n> is unique across all PCI/VIO | 
 |   device slots. | 
 |  | 
 | ibm,drc-indexes: | 
 |   first 4-bytes: BE-encoded integer denoting the number of entries | 
 |   each 4-byte entry: BE-encoded <index> integer that is unique across all DRCs | 
 |     in the machine | 
 |  | 
 |   <index> is arbitrary, but in the case of QEMU we try to maintain the | 
 |   convention used to assign them to pSeries guests on pHyp: | 
 |  | 
 |     bit[31:28]: integer encoding of <type>, where <type> is: | 
 |                   1 for CPU resource | 
 |                   2 for PHB resource | 
 |                   3 for VIO resource | 
 |                   4 for PCI resource | 
 |                   8 for Memory resource | 
 |     bit[27:0]: integer encoding of <id>, where <id> is unique across | 
 |                  all resources of specified type | 
 |  | 
 | ibm,drc-power-domains: | 
 |   first 4-bytes: BE-encoded integer denoting the number of entries | 
 |   each 4-byte entry: 32-bit, BE-encoded <index> integer that specifies the | 
 |     power domain the resource will be assigned to. In the case of QEMU | 
 |     we associated all resources with a "live insertion" domain, where the | 
 |     power is assumed to be managed automatically. The integer value for | 
 |     this domain is a special value of -1. | 
 |  | 
 |  | 
 | ibm,drc-types: | 
 |   first 4-bytes: BE-encoded integer denoting the number of entries | 
 |   each entry: a NULL-terminated <type> string encoded as a byte array | 
 |  | 
 |   <type> is assigned as follows: | 
 |     "CPU" for a CPU | 
 |     "PHB" for a physical host-bridge | 
 |     "SLOT" for a VIO slot | 
 |     "28" for a PCI slot | 
 |     "MEM" for memory resource | 
 |  | 
 | == Guest->Host interface to manage dynamic resources == | 
 |  | 
 | Each DRC is given a globally unique DRC Index, and resources associated with | 
 | a particular DRC are configured/managed by the guest via a number of RTAS | 
 | calls which reference individual DRCs based on the DRC index. This can be | 
 | considered the guest->host interface. | 
 |  | 
 | rtas-set-power-level: | 
 |   arg[0]: integer identifying power domain | 
 |   arg[1]: new power level for the domain, 0-100 | 
 |   output[0]: status, 0 on success | 
 |   output[1]: power level after command | 
 |  | 
 |   Set the power level for a specified power domain | 
 |  | 
 | rtas-get-power-level: | 
 |   arg[0]: integer identifying power domain | 
 |   output[0]: status, 0 on success | 
 |   output[1]: current power level | 
 |  | 
 |   Get the power level for a specified power domain | 
 |  | 
 | rtas-set-indicator: | 
 |   arg[0]: integer identifying sensor/indicator type | 
 |   arg[1]: index of sensor, for DR-related sensors this is generally the | 
 |           DRC index | 
 |   arg[2]: desired sensor value | 
 |   output[0]: status, 0 on success | 
 |  | 
 |   Set the state of an indicator or sensor. For the purpose of this document we | 
 |   focus on the indicator/sensor types associated with a DRC. The types are: | 
 |  | 
 |     9001: isolation-state, controls/indicates whether a device has been made | 
 |           accessible to a guest | 
 |  | 
 |           supported sensor values: | 
 |             0: isolate, device is made unaccessible by guest OS | 
 |             1: unisolate, device is made available to guest OS | 
 |  | 
 |     9002: dr-indicator, controls "visual" indicator associated with device | 
 |  | 
 |           supported sensor values: | 
 |             0: inactive, resource may be safely removed | 
 |             1: active, resource is in use and cannot be safely removed | 
 |             2: identify, used to visually identify slot for interactive hotplug | 
 |             3: action, in most cases, used in the same manner as identify | 
 |  | 
 |     9003: allocation-state, generally only used for "logical" DR resources to | 
 |           request the allocation/deallocation of a resource prior to acquiring | 
 |           it via isolation-state->unisolate, or after releasing it via | 
 |           isolation-state->isolate, respectively. for "physical" DR (like PCI | 
 |           hotplug/unplug) the pre-allocation of the resource is implied and | 
 |           this sensor is unused. | 
 |  | 
 |           supported sensor values: | 
 |             0: unusable, tell firmware/system the resource can be | 
 |                unallocated/reclaimed and added back to the system resource pool | 
 |             1: usable, request the resource be allocated/reserved for use by | 
 |                guest OS | 
 |             2: exchange, used to allocate a spare resource to use for fail-over | 
 |                in certain situations. unused in QEMU | 
 |             3: recover, used to reclaim a previously allocated resource that's | 
 |                not currently allocated to the guest OS. unused in QEMU | 
 |  | 
 | rtas-get-sensor-state: | 
 |   arg[0]: integer identifying sensor/indicator type | 
 |   arg[1]: index of sensor, for DR-related sensors this is generally the | 
 |           DRC index | 
 |   output[0]: status, 0 on success | 
 |  | 
 |   Used to read an indicator or sensor value. | 
 |  | 
 |   For DR-related operations, the only noteworthy sensor is dr-entity-sense, | 
 |   which has a type value of 9003, as allocation-state does in the case of | 
 |   rtas-set-indicator. The semantics/encodings of the sensor values are distinct | 
 |   however: | 
 |  | 
 |   supported sensor values for dr-entity-sense (9003) sensor: | 
 |     0: empty, | 
 |          for physical resources: DRC/slot is empty | 
 |          for logical resources: unused | 
 |     1: present, | 
 |          for physical resources: DRC/slot is populated with a device/resource | 
 |          for logical resources: resource has been allocated to the DRC | 
 |     2: unusable, | 
 |          for physical resources: unused | 
 |          for logical resources: DRC has no resource allocated to it | 
 |     3: exchange, | 
 |          for physical resources: unused | 
 |          for logical resources: resource available for exchange (see | 
 |            allocation-state sensor semantics above) | 
 |     4: recovery, | 
 |          for physical resources: unused | 
 |          for logical resources: resource available for recovery (see | 
 |            allocation-state sensor semantics above) | 
 |  | 
 | rtas-ibm-configure-connector: | 
 |   arg[0]: guest physical address of 4096-byte work area buffer | 
 |   arg[1]: 0, or address of additional 4096-byte work area buffer. only non-zero | 
 |           if a prior RTAS response indicated a need for additional memory | 
 |   output[0]: status: | 
 |                0: completed transmittal of device-tree node | 
 |                1: instruct guest to prepare for next DT sibling node | 
 |                2: instruct guest to prepare for next DT child node | 
 |                3: instruct guest to prepare for next DT property | 
 |                4: instruct guest to ascend to parent DT node | 
 |                5: instruct guest to provide additional work-area buffer | 
 |                   via arg[1] | 
 |             990x: instruct guest that operation took too long and to try | 
 |                   again later | 
 |  | 
 |   Used to fetch an OF device-tree description of the resource associated with | 
 |   a particular DRC. The DRC index is encoded in the first 4-bytes of the first | 
 |   work area buffer. | 
 |  | 
 |   Work area layout, using 4-byte offsets: | 
 |     wa[0]: DRC index of the DRC to fetch device-tree nodes from | 
 |     wa[1]: 0 (hard-coded) | 
 |     wa[2]: for next-sibling/next-child response: | 
 |              wa offset of null-terminated string denoting the new node's name | 
 |            for next-property response: | 
 |              wa offset of null-terminated string denoting new property's name | 
 |     wa[3]: for next-property response (unused otherwise): | 
 |              byte-length of new property's value | 
 |     wa[4]: for next-property response (unused otherwise): | 
 |              new property's value, encoded as an OFDT-compatible byte array | 
 |  | 
 | == hotplug/unplug events == | 
 |  | 
 | For most DR operations, the hypervisor will issue host->guest add/remove events | 
 | using the EPOW/check-exception notification framework, where the host issues a | 
 | check-exception interrupt, then provides an RTAS event log via an | 
 | rtas-check-exception call issued by the guest in response. This framework is | 
 | documented by PAPR+ v2.7, and already use in by QEMU for generating powerdown | 
 | requests via EPOW events. | 
 |  | 
 | For DR, this framework has been extended to include hotplug events, which were | 
 | previously unneeded due to direct manipulation of DR-related guest userspace | 
 | tools by host-level management such as an HMC. This level of management is not | 
 | applicable to PowerKVM, hence the reason for extending the notification | 
 | framework to support hotplug events. | 
 |  | 
 | Note that these events are not yet formally part of the PAPR+ specification, | 
 | but support for this format has already been implemented in DR-related | 
 | guest tools such as powerpc-utils/librtas, as well as kernel patches that have | 
 | been submitted to handle in-kernel processing of memory/cpu-related hotplug | 
 | events[1], and is planned for formal inclusion is PAPR+ specification. The | 
 | hotplug-specific payload is QEMU implemented as follows (with all values | 
 | encoded in big-endian format): | 
 |  | 
 | struct rtas_event_log_v6_hp { | 
 | #define SECTION_ID_HOTPLUG              0x4850 /* HP */ | 
 |     struct section_header { | 
 |         uint16_t section_id;            /* set to SECTION_ID_HOTPLUG */ | 
 |         uint16_t section_length;        /* sizeof(rtas_event_log_v6_hp), | 
 |                                          * plus the length of the DRC name | 
 |                                          * if a DRC name identifier is | 
 |                                          * specified for hotplug_identifier | 
 |                                          */ | 
 |         uint8_t section_version;        /* version 1 */ | 
 |         uint8_t section_subtype;        /* unused */ | 
 |         uint16_t creator_component_id;  /* unused */ | 
 |     } hdr; | 
 | #define RTAS_LOG_V6_HP_TYPE_CPU         1 | 
 | #define RTAS_LOG_V6_HP_TYPE_MEMORY      2 | 
 | #define RTAS_LOG_V6_HP_TYPE_SLOT        3 | 
 | #define RTAS_LOG_V6_HP_TYPE_PHB         4 | 
 | #define RTAS_LOG_V6_HP_TYPE_PCI         5 | 
 |     uint8_t hotplug_type;               /* type of resource/device */ | 
 | #define RTAS_LOG_V6_HP_ACTION_ADD       1 | 
 | #define RTAS_LOG_V6_HP_ACTION_REMOVE    2 | 
 |     uint8_t hotplug_action;             /* action (add/remove) */ | 
 | #define RTAS_LOG_V6_HP_ID_DRC_NAME      1 | 
 | #define RTAS_LOG_V6_HP_ID_DRC_INDEX     2 | 
 | #define RTAS_LOG_V6_HP_ID_DRC_COUNT     3 | 
 |     uint8_t hotplug_identifier;         /* type of the resource identifier, | 
 |                                          * which serves as the discriminator | 
 |                                          * for the 'drc' union field below | 
 |                                          */ | 
 |     uint8_t reserved; | 
 |     union { | 
 |         uint32_t index;                 /* DRC index of resource to take action | 
 |                                          * on | 
 |                                          */ | 
 |         uint32_t count;                 /* number of DR resources to take | 
 |                                          * action on (guest chooses which) | 
 |                                          */ | 
 |         char name[1];                   /* string representing the name of the | 
 |                                          * DRC to take action on | 
 |                                          */ | 
 |     } drc; | 
 | } QEMU_PACKED; | 
 |  | 
 | == ibm,lrdr-capacity == | 
 |  | 
 | ibm,lrdr-capacity is a property in the /rtas device tree node that identifies | 
 | the dynamic reconfiguration capabilities of the guest. It consists of a triple | 
 | consisting of <phys>, <size> and <maxcpus>. | 
 |  | 
 |   <phys>, encoded in BE format represents the maximum address in bytes and | 
 |   hence the maximum memory that can be allocated to the guest. | 
 |  | 
 |   <size>, encoded in BE format represents the size increments in which | 
 |   memory can be hot-plugged to the guest. | 
 |  | 
 |   <maxcpus>, a BE-encoded integer, represents the maximum number of | 
 |   processors that the guest can have. | 
 |  | 
 | pseries guests use this property to note the maximum allowed CPUs for the | 
 | guest. | 
 |  | 
 | == ibm,dynamic-reconfiguration-memory == | 
 |  | 
 | ibm,dynamic-reconfiguration-memory is a device tree node that represents | 
 | dynamically reconfigurable logical memory blocks (LMB). This node | 
 | is generated only when the guest advertises the support for it via | 
 | ibm,client-architecture-support call. Memory that is not dynamically | 
 | reconfigurable is represented by /memory nodes. The properties of this | 
 | node that are of interest to the sPAPR memory hotplug implementation | 
 | in QEMU are described here. | 
 |  | 
 | ibm,lmb-size | 
 |  | 
 | This 64bit integer defines the size of each dynamically reconfigurable LMB. | 
 |  | 
 | ibm,associativity-lookup-arrays | 
 |  | 
 | This property defines a lookup array in which the NUMA associativity | 
 | information for each LMB can be found. It is a property encoded array | 
 | that begins with an integer M, the number of associativity lists followed | 
 | by an integer N, the number of entries per associativity list and terminated | 
 | by M associativity lists each of length N integers. | 
 |  | 
 | This property provides the same information as given by ibm,associativity | 
 | property in a /memory node. Each assigned LMB has an index value between | 
 | 0 and M-1 which is used as an index into this table to select which | 
 | associativity list to use for the LMB. This index value for each LMB | 
 | is defined in ibm,dynamic-memory property. | 
 |  | 
 | ibm,dynamic-memory | 
 |  | 
 | This property describes the dynamically reconfigurable memory. It is a | 
 | property encoded array that has an integer N, the number of LMBs followed | 
 | by N LMB list entires. | 
 |  | 
 | Each LMB list entry consists of the following elements: | 
 |  | 
 | - Logical address of the start of the LMB encoded as a 64bit integer. This | 
 |   corresponds to reg property in /memory node. | 
 | - DRC index of the LMB that corresponds to ibm,my-drc-index property | 
 |   in a /memory node. | 
 | - Four bytes reserved for expansion. | 
 | - Associativity list index for the LMB that is used as an index into | 
 |   ibm,associativity-lookup-arrays property described earlier. This | 
 |   is used to retrieve the right associativity list to be used for this | 
 |   LMB. | 
 | - A 32bit flags word. The bit at bit position 0x00000008 defines whether | 
 |   the LMB is assigned to the the partition as of boot time. | 
 |  | 
 | [1] http://thread.gmane.org/gmane.linux.ports.ppc.embedded/75350/focus=106867 |